Description
Cardioversor Monitor Biphasic Defibrillator
PRACTICAL
- Light.
- Strong, comfortable strap.
- Ready to use in less than 6 seconds.
- Designed without sharp edges, ideal for emergency transport.
- Biphase power delivery of up to 360 Joules.
- The battery, which is easy to replace, allows more than 100 shocks.
SMART
- Interface that automatically adjusts to the number of parameters, presenting the important information in a clearer and more organized way.
- Smart monitoring alarms.
EASY TO USE
- All operations are concentrated in only two buttons.
- Easy operation – 1, 2, 3 standard.
- Integrated adult/children pads.
- Quick access to main functions.
VERSATILE
The CardioMax can become even more complete and convenient through various optional items available that help accompany high-risk patients:
- AED Module – Automated External Defibrillator
- Real Time Check technology
- Sudden Death Prevention technology
- Charge Auto-Sequencing technology
CHARACTERISTICS
- Real Time Check Technology (RTC)**
- Automated External Defibrillator Mode (AED)
- Sudden Death Prevention Mode (SDP)
- Electrocardiogram (ECG) up to 12 derivations
- Oximetry (SpO2)
- Non invasive pacemaker
- Non invasive pressure (NIBP)
- Capnography (EtCO2)
- Printer
- Removable rechargeable battery – part number 27007
TECHNICAL INFORMATION
GENERAL SPECIFICATIONS
- Dimensions with pads:
- 30,0 cm (11.81 in) length.
- 21,5 cm (8.46 in) depth.
- 28,0 cm (11.02 in) height.
- Weight:
- Device – 5.15 kg (11.35 lbs).
- NiMH battery (27007) – 1.10 kg (2.43 lbs).
- Li-Ion battery – 0.60 kg (1.32 lbs).
- External pads – 0.85 kg (1.87 lbs).
- Complete set (NiMH battery) – 7.10 kg (15.66 lbs) (except NIBP).
- Complete set (Li-Ion battery) – 6.60 kg (15.66 lbs) (except NIBP).
- Electrical:
- AC: 100 to 265 VAC, 50/60 Hz (automatic selection).
- DC external: 11 to 16 VDC.
- Removable rechargeable battery:
- Type: NiMH, 14.4 VDC 4.5 A/h.
- Duration: Battery with full charge – 3 hours in monitor mode, without printer, or a minimum of 140 shocks at 360 joules or a minimum of 200 shocks at 200 joules.
- Battery full-charge time (when fully unloaded): 8 hours.
- OPTIONAL BATTERY**:
- Type: Li-Ion, 14.8 VDC 4.4 A/h.
- Duration: Battery with full charge – 3v hours in monitor mode, without printer, or a minimum of 140 shocks at 360 Joules or a minimum of 200 shocks at 200 joules.
- Battery full-charge time (when fully unloaded): 8 hours.
**Consult availability.
- Memory:
- Type: Nand Flash.
- Capacity: 2 Mbytes.
- Patients stored >150 patients. – Storage: 15 seconds of ECG when in shock, physiological alarm and panel events.
- ECG: 2 continuous hours of ECG curve recording, when in AED mode.
- RTC – Real Time Check (available when equipped with Li-lon optional battery):
- Defibrillation self-test, battery level, connected pads, power source connection check. Check is performed 3 times which are set in advance. This information is wirelessly transmitted to a PC with RTC System software installed and within range of the network.
ENVIRONMENTAL SPECIFICATIONS
- Temperature:
- Operational: 0 to 50°C.
- Storage: -20 to 50°C.
- Humidity:
- Operational: 10 to 95% RH, without condensation.
- Storage: 10 to 95% RH, without condensation.
- IP Rating: IPX1.
DEFIBRILLATOR
- Waveform:
- Biphasic truncated exponential. Waveform parameters adjusted in terms of patient’s impedance.
- Shock application:
- By means of multifunctional pads (adhesive) or defibrillation pads.
- Adult/external defibrillation:
- Scales:1,2,3,4,5,6,7,8,9, 10, 20, 30, 50, 80, 100, 150, 200, 250, 300 and 360 Joules. Maximum power limited to 50 J with internal or children’s pads.
- Controls: On/Off button, charge, shock, synchronism.
- Power selection: Therapy button on the front panel.
- Charge control: Button on the front panel, button on the external pads.
- Shock control: Button on the front panel, buttons on the external pads.
- Synchronized control: SYNC button on the front panel.
- Charge Auto-Sequencing:
- When enabled, it charges power previously set by the user for the first, second and third shocks, with no need to manually adjust the selector.
- Charge indicators:
- Sound signal of equipment being charged.
- Sound signal of completed charge.
- LED on external pads and charge level indicated on the display.
- Maximum charging time:
- (200J): mains supply and battery < 4s.
- (360J): mains supply and battery < 6s.
- Electrode size:
- Adult: 10.3 cm (4.05 in) x 8.5 cm (3.34 in). Contact area: 81.9 cm2 (12.69 in2)
- Children: 4.5 cm (1.77 in) x 4.0 2 cm (1.57 in). Contact area: 18 cm2 (2.79 in2)
- Cardioversion:
- < 60 ms.
- Pads (options):
- Adult and child external (included).
- Adult and child internal (optional).
- Multifunctional for pacemaker, monitoring and defibrillation (optional).
- Multifunctional extension (optional).
AED MODULE
- Functional characteristics:
- Voice instructions, visual indications, CPR instructions, USB 2.0. Multilanguage, Sudden Death Prevention Technology (SDP).
- USB:
- USB 2.0 for transfer of the electrocardiogram stored in AED mode to a compatible PC.
- SoftDEA:
- Software for viewing the data transferred to the PC.
EXTERNAL PACEMAKER (OPTIONAL)
- Modes:
- Demand or fixed.
- Amplitude:
- From 5 mA to 200 mA (resolution of 5 mA), accuracy 10%.
- Pulse width:
- 20 ms (± 1 ms).
- Frequency:
- From 30 ppm to 180 ppm (increments of 5 ppm), accuracy ± 2%.
- Refractory period:
- 340 ms (from 30 to 80 ppm).
- 240 ms (from 90 to 180 ppm).
NIBP (OPTIONAL)
- Operating principle:
- Oscillometric.
- Automatic measurement mode:
- 1, 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
- Manual:
- One measurement.
- Measurement interval:
- Adult:
- Systolic: 40 – 260 mmHg.
- MAP: 26 – 220 mmHg.
- Diastolic: 20 – 200 mmHg.
- Paediatric:
- Systolic: 40 – 160 mmHg.
- MAP: 26 – 133 mmHg.
- Diastolic: 20 – 120 mmHg.
- Neonate:
- Systolic: 40 – 130 mmHg.
- MAP: 26 – 110 mmHg.
- Diastolic: 20 – 100 mmHg.
- Overpressure protection by hardware:
- Adult: 300 ± mmHg.
- Neonate: 150 ± mmHg.
- Overpressure protection by hardware:
- Adult: 300 ± mmHg.
- Neonate: 150 ± mmHg.
- Resolution:
- 1 mmHg.
CPR Maestro**
- Accessory for Cardiopulmonary Resuscitation
- Feedback of the thoracic compressions.
DISPLAY
- Battery level indicator:
- Yes.
- Size:
- 128.2 mm x 170.9 mm.
- Diagonal:
- 8.4”.
- Type:
- Colour LCD TFT.
- Resolution:
- 640 x 480 pixels (VGA).
- Scan speed:
12.5; 25 and 50 mm/s.
ECG (supports up to 12 simultaneous derivations when equipped with optional cable)
- Inputs:
- 3 or 5 lead ECG cable.
- 10 lead ECG cable (optional).
- External pads.
- Multifunctional pads.
- Range:
- 15 to 350 BPM.
- Precision:
- ± 1 BPM from 15 to 350 BPM.
- Rejection in common mode:
- Greater than 90 dB, measured according to AAMI standards for heart monitors (EC 13).
- Sensitivity:
- 5, 10, 15, 20, 30 and 40 mm/mV.
- AC line filter:
- 60 Hz or 50 Hz.
- ECG response frequency:
- Diagnostic mode – (0.05 -100 Hz).
- Monitor Mode – (1-40 Hz).
- Patient insulation:
- Defibrillation proof.
- ECG: CF Type.
- SpO2: CF Type.
- Loose electrode:
- Identified and shown with low level alarm.
- Time to restore ECG baseline after defibrillation:
- ≤ 3 seconds.
SpO2 (OPTIONAL)
- SpO2 range:
- 0 to 100%.
- Pulse range:
- 30 to 250 BPM.
- SpO2 precision:
- ± 2 % from 70 to 100%.
- ± 3 % from 50 to 69%.
- Pulse precision:
- ± 2 BPM.
- Scan speed:
- 12.5; 25 e 50 mm/s.
CAPNOGRAPHY (OPTIONAL)
- Measurement range CO2:
- 0 – 99 mmHg.
- Precision:
- ± 2 mmHg (0 – 38 mmHg).
- ± 5% + 0.08% for each 1mmHg above 38 mmHg (39 – 99mmHg).
- Consumption:
- 1.5 W.
- Compensation:
- BTPS, N2O, O2.
PRINTER (OPTIONAL)
- Prints up to three simultaneous derivations.
- Type:
- Thermal.
- Weight:
- 0.4 kg.
- Speed:
- 12.5; 25 or 50 mm/s with precision of ± 5%.
- Paper size:
- 58 mm (width) x 15 m (maximum length).
STANDARDS
- NBR IEC 60601-1
- NBR IEC 60601-1-2
- NBR IEC 60601-1-6
- NBR IEC 60601-1-8
- NBR IEC 60601-2-4
- NBR IEC 60601-2-27
- NBR IEC 60601-2-30
- NBR IEC 60601-2-49
or equivalent IECs
For further information or to discuss our range of Original Manufacturer medical batteries & Compatible medical batteries, Original Manufacturer medical accessories and general purpose Sealed Lead Acid/VRLA batteries contact our friendly & knowledgeable Customer Service team on 0116 2340567 or email info@euroenergy.co.uk
Additional information
Weight | 1.009 kg |
---|