Here to support our NHS during the COVID-19 crisis
Request callback Contact Us
Loading Zoom, please wait
Instramed Cardiomax battery - 27007 Original Medical Battery

Instramed Cardiomax battery - 27007 Original Medical Battery

Price
Not Orderable Online

Product Description

Euro Energy Part Number: 02388
Instramed Cardiomax 27007 Original Medical Battery
Instramed part Number: 27007
Voltage/Capacity: 14.4V/4500mAh
Approx Size: 210mm L x 63.6mm W x 60.8mm H
Approx Weight: 1009g
Chemistry: Nickel Metal Hydride (NiMH)
 
This is a genuine original battery for use in the Instramed Cardiomax, part number 27007.
 

Cardioversor Monitor Biphasic Defibrillator

 

PRACTICAL

  • Light.
  • Strong, comfortable strap.
  • Ready to use in less than 6 seconds.
  • Designed without sharp edges, ideal for emergency transport.
  • Biphase power delivery of up to 360 Joules.
  • The battery, which is easy to replace, allows more than 100 shocks.

SMART

  • Interface that automatically adjusts to the number of parameters, presenting the important information in a clearer and more organized way.
  • Smart monitoring alarms.

EASY TO USE

  • All operations are concentrated in only two buttons.
  • Easy operation - 1, 2, 3 standard.
  • Integrated adult/children pads.
  • Quick access to main functions.

VERSATILE

The CardioMax can become even more complete and convenient through various optional items available that help accompany high-risk patients:

  • AED Module - Automated External Defibrillator
  • Real Time Check technology
  • Sudden Death Prevention technology
  • Charge Auto-Sequencing technology

CHARACTERISTICS

  • Real Time Check Technology (RTC)**
  • Automated External Defibrillator Mode (AED)
  • Sudden Death Prevention Mode (SDP)
  • Electrocardiogram (ECG) up to 12 derivations
  • Oximetry (SpO2)
  • Non invasive pacemaker
  • Non invasive pressure (NIBP)
  • Capnography (EtCO2)
  • Printer
  • Removable rechargeable battery - part number 27007

TECHNICAL INFORMATION

GENERAL SPECIFICATIONS

  • Dimensions with pads:
  • 30,0 cm (11.81 in) length.
  • 21,5 cm (8.46 in) depth.
  • 28,0 cm (11.02 in) height.
  • Weight:
  • Device - 5.15 kg (11.35 lbs).
  • NiMH battery (27007) - 1.10 kg (2.43 lbs).
  • Li-Ion battery - 0.60 kg (1.32 lbs).
  • External pads - 0.85 kg (1.87 lbs).
  • Complete set (NiMH battery) - 7.10 kg (15.66 lbs) (except NIBP).
  • Complete set (Li-Ion battery) - 6.60 kg (15.66 lbs) (except NIBP).
  • Electrical:
  • AC: 100 to 265 VAC, 50/60 Hz (automatic selection).
  • DC external: 11 to 16 VDC.
  • Removable rechargeable battery:
  • Type: NiMH, 14.4 VDC 4.5 A/h.
  • Duration: Battery with full charge - 3 hours in monitor mode, without printer, or a minimum of 140 shocks at 360 joules or a minimum of 200 shocks at 200 joules.
  • Battery full-charge time (when fully unloaded): 8 hours.
  • OPTIONAL BATTERY**:
  • Type: Li-Ion, 14.8 VDC 4.4 A/h.
  • Duration: Battery with full charge - 3v hours in monitor mode, without printer, or a minimum of 140 shocks at 360 Joules or a minimum of 200 shocks at 200 joules.
  • Battery full-charge time (when fully unloaded): 8 hours.

**Consult availability.

  • Memory:
  • Type: Nand Flash.
  • Capacity: 2 Mbytes.
  • Patients stored >150 patients. - Storage: 15 seconds of ECG when in shock, physiological alarm and panel events.
  • ECG: 2 continuous hours of ECG curve recording, when in AED mode.
  • RTC – Real Time Check (available when equipped with Li-lon optional battery):
  • Defibrillation self-test, battery level, connected pads, power source connection check. Check is performed 3 times which are set in advance. This information is wirelessly transmitted to a PC with RTC System software installed and within range of the network.

ENVIRONMENTAL SPECIFICATIONS

  • Temperature:
  • Operational: 0 to 50°C.
  • Storage: -20 to 50°C.
  • Humidity:
  • Operational: 10 to 95% RH, without condensation.
  • Storage: 10 to 95% RH, without condensation.
  • IP Rating: IPX1.
     

DEFIBRILLATOR

  • Waveform:
  • Biphasic truncated exponential. Waveform parameters adjusted in terms of patient’s impedance.
  • Shock application:
  • By means of multifunctional pads (adhesive) or defibrillation pads.
  • Adult/external defibrillation:
  • Scales:1,2,3,4,5,6,7,8,9, 10, 20, 30, 50, 80, 100, 150, 200, 250, 300 and 360 Joules. Maximum power limited to 50 J with internal or children’s pads.
  • Controls: On/Off button, charge, shock, synchronism.
  • Power selection: Therapy button on the front panel.
  • Charge control: Button on the front panel, button on the external pads.
  • Shock control: Button on the front panel, buttons on the external pads.
  • Synchronized control: SYNC button on the front panel.
  • Charge Auto-Sequencing:
  • When enabled, it charges power previously set by the user for the first, second and third shocks, with no need to manually adjust the selector.
  • Charge indicators:
  • Sound signal of equipment being charged.
  • Sound signal of completed charge.
  • LED on external pads and charge level indicated on the display.
  • Maximum charging time:
  • (200J): mains supply and battery < 4s.
  • (360J): mains supply and battery < 6s.
  • Electrode size:
  • Adult: 10.3 cm (4.05 in) x 8.5 cm (3.34 in). Contact area: 81.9 cm2 (12.69 in2)
  • Children: 4.5 cm (1.77 in) x 4.0 2 cm (1.57 in). Contact area: 18 cm2 (2.79 in2)
  • Cardioversion:
  • < 60 ms.
  • Pads (options):
  • Adult and child external (included).
  • Adult and child internal (optional).
  • Multifunctional for pacemaker, monitoring and defibrillation (optional).
  • Multifunctional extension (optional).

AED MODULE

  • Functional characteristics:
  • Voice instructions, visual indications, CPR instructions, USB 2.0. Multilanguage, Sudden Death Prevention Technology (SDP).
  • USB:
  • USB 2.0 for transfer of the electrocardiogram stored in AED mode to a compatible PC.
  • SoftDEA:
  • Software for viewing the data transferred to the PC.

EXTERNAL PACEMAKER (OPTIONAL)

  • Modes:
  • Demand or fixed.
  • Amplitude:
  • From 5 mA to 200 mA (resolution of 5 mA), accuracy 10%.
  • Pulse width:
  • 20 ms (± 1 ms).
  •  Frequency:
  • From 30 ppm to 180 ppm (increments of 5 ppm), accuracy ± 2%.
  • Refractory period:
  • 340 ms (from 30 to 80 ppm).
  • 240 ms (from 90 to 180 ppm).

NIBP (OPTIONAL)

  • Operating principle:
  • Oscillometric.
  • Automatic measurement mode:
  • 1, 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
  • Manual:
  • One measurement.
  • Measurement interval:
  • Adult:
  • Systolic: 40 - 260 mmHg.
  • MAP: 26 - 220 mmHg.
  • Diastolic: 20 - 200 mmHg.
  • Pediatric:
  • Systolic: 40 - 160 mmHg.
  • MAP: 26 - 133 mmHg.
  • Diastolic: 20 - 120 mmHg.
  • Neonate:
  • Systolic: 40 - 130 mmHg.
  • MAP: 26 - 110 mmHg.
  • Diastolic: 20 - 100 mmHg.
  • Overpressure protection by hardware:
  • Adult: 300 ± mmHg.
  • Neonate: 150 ± mmHg.
  • Overpressure protection by hardware:
  • Adult: 300 ± mmHg.
  • Neonate: 150 ± mmHg.
  •  Resolution:
  • 1 mmHg.

CPR Maestro**

  • Accessory for Cardiopulmonary Resuscitation
  • Feedback of the thoracic compressions.

DISPLAY

  • Battery level indicator:
  • Yes.
  • Size:
  • 128.2 mm x 170.9 mm.
  • Diagonal:
  • 8.4”.
  • Type:
  • Color LCD TFT.
  • Resolution:
  • 640 x 480 pixels (VGA).
  • Scan speed:

12.5; 25 and 50 mm/s.

ECG (supports up to 12 simultaneous derivations when equipped with optional cable)

  • Inputs:
  • 3 or 5 lead ECG cable.
  • 10 lead ECG cable (optional).
  • External pads.
  • Multifunctional pads.
  • Range:
  • 15 to 350 BPM.
  • Precision:
  • ± 1 BPM from 15 to 350 BPM.
  • Rejection in common mode:
  • Greater than 90 dB, measured according to AAMI standards for heart monitors (EC 13).
  • Sensitivity:
  • 5, 10, 15, 20, 30 and 40 mm/mV.
  • AC line filter:
  • 60 Hz or 50 Hz.
  • ECG response frequency:
  • Diagnostic mode - (0.05 -100 Hz).
  • Monitor Mode - (1-40 Hz).
  • Patient insulation:
  • Defibrillation proof.
  • ECG: CF Type.
  • SpO2: CF Type.
  • Loose electrode:
  • Identified and shown with low level alarm.
  • Time to restore ECG baseline after defibrillation:
  • ≤ 3 seconds.

SpO2 (OPTIONAL)

  • SpO2 range:
  • 0 to 100%.
  • Pulse range:
  • 30 to 250 BPM.
  • SpO2 precision:
  • ± 2 % from 70 to 100%.
  • ± 3 % from 50 to 69%.
  • Pulse precision:
  • ± 2 BPM.
  • Scan speed:
  • 12.5; 25 e 50 mm/s.

CAPNOGRAPHY (OPTIONAL)

  • Measurement range CO2:
  • 0 – 99 mmHg.
  • Precision:
  • ± 2 mmHg (0 – 38 mmHg).
  • ± 5% + 0.08% for each 1mmHg above 38 mmHg (39 – 99mmHg).
  • Consumption:
  • 1.5 W.
  • Compensation:
  • BTPS, N2O, O2.

PRINTER (OPTIONAL)

  • Prints up to three simultaneous derivations.
  • Type:
  • Thermal.
  • Weight:
  • 0.4 kg.
  • Speed:
  • 12.5; 25 or 50 mm/s with precision of ± 5%.
  • Paper size:
  • 58 mm (width) x 15 m (maximum length).

STANDARDS

  • NBR IEC 60601-1
  • NBR IEC 60601-1-2
  • NBR IEC 60601-1-6
  • NBR IEC 60601-1-8
  • NBR IEC 60601-2-4
  • NBR IEC 60601-2-27
  • NBR IEC 60601-2-30
  • NBR IEC 60601-2-49

or equivalent IECs

For further information or to discuss our range of Original Manufacturer medical batteries & Compatible medical batteries, Original Manufacturer medical accessories and general purpose Sealed Lead Acid/VRLA batteries contact our friendly & knowledgeable Customer Service team on 0116 2340567 or email info@euroenergy.co.uk

Ref: 02388 Shipping Weight: 1.009kgs
Registered Name: Euro Energy Resources Limited
Registered Office: 10 Barrington Business Park, Leycroft Road, Leicester, LE4 1ET, UK
Global Location Number: 5060554170005 | Registered Number: 01576945 | VAT Number GB355306562